LFL1.133 Siemens Burner Accessories Siemens LFL series gas burner controller

LFL1.133 Siemens Burner Accessories Siemens LFL series gas burner controller

SKU: #001 - In Stock
USD$156.00 USD$156.00 (% off)

  • airport Shipping:  International shipping available
  •  Shipping time:   Standar(10-20 business days), Rush(5-10 business days)
  • chip Discount:  Get 2% discount on orders of USD $100.00,Get 3% discount on orders of USD $200.00
  • compass Handling time:  Ships within 3 business days after receiving cleared payment
  • available_updates Returns:  7 days money back guaratee,buyer pays return shipping

Product Detail

Customer Reviews

Shipping Guide

Delivery Time

Product Tags

LFL series gas burner controller:

Technical performance and structural characteristics:

Control and monitor intermittently operating multi-stage or continuously proportional medium to large gas, oil or dual fuel forced draft burners.

Controls have an expanding flame and an interruptible ignition burner.

With damper position detection.

LFL1.638 is suitable for large capacity natural draft burners.

LFL1.148——Large and medium capacity single-stage or double-stage atmospheric intermittent operation combustion controller.

Use features:

LFL1…Burner control unit Designed for forced draught burner control and monitoring Can be used for direct ignition or medium to high power burners with ignition burners Oil gas universal and can be used for stationary preheating air burners WLE according to DIN 4794 standard 01 The difference between the series and the 02 series is that the safety time of the ignition burner with ignition gas valve is different. The high-power atmospheric combustion controller chooses LFL1.638. If the burner needs continuous operation control, please refer to LGK 16…Technical data

Installation Precautions:

Installation Notes: 1. The controller unit and other cables must be installed separately from the high-voltage ignition cable.

2. Do not confuse phase and neutral.

3. Installation of switches, fuses, grounding, etc. must follow local regulations.

4. It must be confirmed that the maximum current allowed by the terminal is not exceeded.

5. Do not connect the main power supply to the output terminal of the combustion controller.

6. Isolate the burner controller from the mains power supply with an all-polar switch, leaving at least a 3mm contact gap.

7. Protect the ground bushing under the chassis with a metric screw and loose washer.

8. An AGK25 must be connected to terminal 3 of the controller without the use of a fan, otherwise the burner will not start reliably.

9. For safety, connect the neutral conductor to the neutral distributor or terminal 2 on the bottom of the insert block. Combustion components (fans, ignition transformers, and gas valves) are listed in Figure 7435a14 and must be connected to the neutral conductor as shown below.

10. The connection between the neutral conductor and terminal 2 is pre-wired at the bottom of the control unit.

Features:

1. The unit allows the burner with or without post-purge.

2. The fan motor current is less than 4A and the maximum starting current is 20A, which can be directly connected.

3. Separate control output damper actuator switch and min.

4. Monitor damper control to ensure rated air volume during pre-purge Check start position closed or minimum low load position, open at the beginning and minimum position after pre-purge time is over when the actuator does not actuate the damper to reach the predetermined position burner start-up procedure will be aborted.

5. The wind pressure monitoring function test from the air pressure monitoring before starting and the blowing until the control shutdown stage.

6. The separate ignition fuel valve control output is cut off after the second safety time.

7.2 Fuel release control outputs have a 3rd stage control output or load control if necessary.

8. Simple measures can be taken to increase the safety time from 2.5 seconds to 5 seconds when the Series 1 programmable controller is directly fired. See Engineering Notes to provide longer safety times to accommodate local safety regulations.

9. When the load control is activated, the control output of the damper actuator is independent of other control part circuits.

10. Connect remote reset device for remote reset and remote emergency shutdown

Technical parameters of LFL series gas burner controller:

Model LFL1.122 LFL1.133 LFL1.322 LFL1.133 LFL1.135 LFL1.622 LFL1.635 LFL1.638
10s 9s 36s 31.5 37.5s 66s 67.5s 67.5s
TAS 2s 3s 2s 3s 2.5s 2s 2.5s 2.5s
TAS’ / / / / 5s / 5s 5s
t3 4s 3s 4s 6s 5s 4s 5s 5s
t3′ / / / / 2.5s / 2.5s 2.5s
t4 6s 6s 10s 12s 12.5s 10s 12.5s 12.5s
4′ / / / / 15s / 15s 15s
t5 4s 3s 10s 12s 12.5s 10s 12.5s 12.5s
t6 10s 14.5s 12s 18s 15s 12s 15s 15s
t7 2s 3s 2s 3s 2.5s 2s 2.5s 2.5s
t8 30s 29 60s 72s 78s 96s 105s 105s
t9 2s 3s 2s 3s 5s 2s 5s 5s
t10 6s 6s 8s 12s 10s 8s 10s 10s
t11 可选
t12 可选
t13 10s 14.5s 12s 18s 15s 12s 15s 15s
t16 4s 3s 4s 6s 5s 4s 5s 5s
t20 32s 60s / 27s 22.5s / / /
Remark Ignition monitoring Ignition monitoring Fixed air heating Large capacity atmospheric burner

t1 Pre-purging time TAS safe ignition time TAS second safe ignition time t3 Pre-ignition time

t3′ pre-ignition time, terminal 17 release voltage t4 from t2 to terminal 19 release voltage

t5 from the end of t4 to the release voltage of terminal 20 Purge time after t6 t7 Start command to release voltage of terminal 7

t9 Second safety time t10 Start to wind pressure control start t11 Throttle fully open time t12 Throttle fully closed time

t13 Post-purging time after allowable shutdown t16 Interval from start command to full throttle opening command

At t20, there is no post-purging after shutdown, and the interval until the next start

 

Model:
--- Please Select ---

Write a review here:

  • 1 Star2 Stars3 Stars4 Stars5 Stars (No Ratings Yet)
    Loading ... Loading ...

  • seven × 7 =

  • JPEG only
  • The following is the process you should take to complete your order through bank to bank transfer:

    1. Please go to your bank (through online banking, ATM or going into a branch) and complete the transfer of money. Make sure that the amount you transfer is the exact total of your order. Payment details below:

    - If your bank is located in Austria, Germany, Spain, France, United Kingdom, Italy, Netherlands, Belgium, Finland, Greece or Luxemburg you will pay to our WorldPay bank. You will see the bank details once you have placed the order.

    PLEASE NOTE: If you are paying to our WorldPay bank you MUST include the Unique Payment Reference Number (you will receive this directly after paying the order) in the description section when completing payment to help us identify your order. Failure to do this will result in an unsuccessful transaction.

    - If your bank is located in a country not listed above you will pay to our HSBC account. The details are below:

    Bank Account:
    Bank Code:
    Beneficiary:
    Bank Name:
    Bank Address:
    SWIFT Code:

    PLEASE NOTE: If you are paying in this way you MUST write your Yourname order number in the description section when paying so we can easily recognize your payment. Failure to do this will result in a delayed or failed transaction.

    2. When this is done, log in to your Yourname ‘My Account’ and complete the following:

    Click ‘Order list’
    Click ‘Pay’
    Click ‘Complete Payment’ and fill in the related information for verification (This is an important step. If the information you have filled in does not match your bank details the payment can not be completed.)
    Click ‘Submit’ to finish the procedure.

    3. You will receive a payment confirmation email from us after your order’s payment has gone through successfully. If you do not receive this email, please contact us here: http://www.Yourname.com/help/

    Please note that Yourname will begin to handle your items after payment has been cleared.

    The tailoring and handling time is the number of business days we will take to process your items before shipping them. This processing includes order verification, item manufacturing, quality checking and packaging. This does not include the shipping time.

    Different items and categories have different tailoring and handling times. However, on each item page the information is displayed next to the item photo as shown in the picture below.

    Tags: , , , , , , , , ,

    Customers Also Bought:

    INQUIRY DETAILS *

    INQUIRY NOW
    • captcha