Hi, Sign in
Intelligent regulating valve 02R Smart Wireless Type high brightness high-speed opening
product description
Valves that can be assembled: straight ball valve, three-way ball valve, butterfly valve
Rated voltage: AC/DC95V-265V, AC/DC24V
Communication method: RF433/868/915MHZ, FSK, LORA, RF Ocean (single control type)
Communication protocol: (compatible with modbus)
Communication distance: 3Km
Features: high-speed quick opening / power-off reset
Available: two-position mode, three-position mode
High-performance brushless motor with built-in overload protection
Lifespan up to 20,000 times
All plastic shell: ABS /PC+PET
Die-cast aluminum housing, surface passivation sprayed
Features
The 1.3-inch OLED large-screen LCD is used to display the valve opening and its external control commands in real time. It will automatically enter the sleep state after about 5 minutes, and will prompt the position status and its control commands during the sleep period.
Innovative cap-free regulating valve mode: the intelligent bus type is the same as the intelligent switch type regulating valve.
Real-time prompts in the fault menu (including the fault caused by the actuator being stuck or the actuator switch is not in place due to other reasons).
Parameters can be dynamically changed through the menu, including bus ID address, baud rate, communication frequency, frequency band, attenuation gain and other parameters.
The automatic switching between remote control and on-site control can be realized through the menu, and the valve can be opened and closed through the button.
A repeater (USB interface) can be provided as required, which is convenient for users to operate with serial ports on the host computer and reduces the difficulty of using the user system.
The switching speed of the valve can be adjusted in real time through the menu.
The system can be restored to factory settings by key operation.
technical parameterO33:Y46O33:Y48O33:Y45 | ||||||||||
standard product | ||||||||||
model | Rated torque | Voltage | time | communication method | Rotation angle | Protection class | Manual function | location indication | shell material | Output shaft |
02R | 20Nm | AC/DC24V | 10s | FSK/LORA (Modbus) | 90°/180° | IP67/F type | Hex key | Mechanical indication | ABS/Die Cast Aluminum | Inside the eight directions |
AC/DC95-265V | RF 433/868M/915M RF Ocean Single Control | ≤330° | Manual button | OLED display | outside the Quartet | |||||
High speed quick opening | ||||||||||
model | Rated torque | Voltage | time | communication method | Rotation angle | Protection class | Manual function | location indication | shell material | Output shaft |
02RH | 15Nm | DC24V | 1s | FSK/LORA (Modbus) | 90°/180° | IP67/F type | Hex key | Mechanical indication | ABS/Die Cast Aluminum | Inside the eight directions |
RF 433/868M/915M RF Ocean Single Control | ≤330° | Manual button | OLED display | outside the Quartet | ||||||
Power-off reset type | ||||||||||
model | Rated torque | Voltage | time | communication method | Rotation angle | Protection class | Manual function | location indication | shell material | Output shaft |
02R-KT | 15Nm | AC/DC24V | 15s | FSK/LORA (Modbus) | 90°/180° | IP67/F type | Hex key | Mechanical indication | ABS/Die Cast Aluminum | Inside the eight directions |
AC/DC95-265V | RF 433/868M/915M RF Ocean Single Control | ≤330° | Manual button | OLED display | outside the Quartet |
The following is the process you should take to complete your order through bank to bank transfer:
1. Please go to your bank (through online banking, ATM or going into a branch) and complete the transfer of money. Make sure that the amount you transfer is the exact total of your order. Payment details below:
- If your bank is located in Austria, Germany, Spain, France, United Kingdom, Italy, Netherlands, Belgium, Finland, Greece or Luxemburg you will pay to our WorldPay bank. You will see the bank details once you have placed the order.
PLEASE NOTE: If you are paying to our WorldPay bank you MUST include the Unique Payment Reference Number (you will receive this directly after paying the order) in the description section when completing payment to help us identify your order. Failure to do this will result in an unsuccessful transaction.
- If your bank is located in a country not listed above you will pay to our HSBC account. The details are below:
Bank Account:
Bank Code:
Beneficiary:
Bank Name:
Bank Address:
SWIFT Code:
PLEASE NOTE: If you are paying in this way you MUST write your Yourname order number in the description section when paying so we can easily recognize your payment. Failure to do this will result in a delayed or failed transaction.
2. When this is done, log in to your Yourname ‘My Account’ and complete the following:
Click ‘Order list’
Click ‘Pay’
Click ‘Complete Payment’ and fill in the related information for verification (This is an important step. If the information you have filled in does not match your bank details the payment can not be completed.)
Click ‘Submit’ to finish the procedure.
3. You will receive a payment confirmation email from us after your order’s payment has gone through successfully. If you do not receive this email, please contact us here: http://www.Yourname.com/help/
Please note that Yourname will begin to handle your items after payment has been cleared.
The tailoring and handling time is the number of business days we will take to process your items before shipping them. This processing includes order verification, item manufacturing, quality checking and packaging. This does not include the shipping time.
Different items and categories have different tailoring and handling times. However, on each item page the information is displayed next to the item photo as shown in the picture below.