The RS/1 series burners have outputs ranging from 163 to 465 KW and are designed for use in hot or superheated boilers, hot air generators or steam boilers, and heat transfer oil boilers. The adjustment method is “one stage fire”. The fan with forward-leaning blades and the installation of sound insulation material at the air inlet of the fan ensure the reduction of noise emission.
The improvement of the performance of the combustion head of the fan increases the scope of application of the burner and ensures the combustion efficiency of each operating point.
Some advanced designs of this type of burner make the burner smaller in size and convenient for use and maintenance. Additional options ensure the burner’s working flexibility.
With outputs ranging from 70 to 2290 kW, the RS series burners are designed for use in hot or superheated boilers, hot air generators or steam boilers and heat transfer oil furnaces.
The adjustment method is “smooth transition of two stages of fire”. The burner is equipped with a microelectronic control box, which can provide the burner operating status and fault cause diagnosis.
The improvement of the performance of the fan and the combustion head increases the scope of application of the burner and ensures the combustion efficiency at each operating point.
The advanced design of this type of burner makes it smaller in size, convenient for use and maintenance, and more optional accessories can ensure that the function of the burner can be upgraded at any time. The figure below shows the minimum pressure loss of the gas manifold that can match the burner; add the back pressure of the combustion chamber to obtain the total burner gas pressure loss.
Riello RS 34/1T.C series gas burner technical parameters:
Burner technical parameters | ||||||
model | RS34/1 | RS44/1 | RS34 | RS44 | RS50 | |
Adjustment method | single stage fire | single stage fire | smooth second stage | smooth second stage | smooth second stage | |
— | — | 2—1 | 2—1 | 2—1 | ||
servo motor | model | — | — | SQN90 | SQN90 | SQN90 |
operation hours | — | — | 12 | 12 | 12 | |
heat output | KW | 70-390 | 101-550 | 70/125-390 | 100/200-550 | 85/290 |
580 | ||||||
Mcal/h | 60-335 | 87-473 | 90/200+378 | 86/172+437 | 73/249 | |
499 | ||||||
working environment | ℃min./max | 60 | 60 | 60 | 60 | 60 |
power supply | Ph/Hz/V | 1/50/230~±10% | ||||
control box | model | RMG | RMG | RMG | RMG | RMG |
control electric power | KW | 0.3 | 0.42 | 0.56 | 0.7 | 0.7 |
Rated current | A | 3.2 | 3.2 | 0.12 | 0.28 | 0.28 |
Protection level | IP | 54 | 54 | 44 | 40 | 40 |
Motor Power | KW | 0.3 | 0.42 | 0.42 | 0.42 | 0.42 |
Motor rated current | A | 3.2 | 3.5 | 2.9 | 3.5 | 3.5 |
Motor starting current | A | 15 | 17 | 11 | 17 | 17 |
Motor protection class | IP | 54 | 54 | 54 | 40 | 40 |
ignition voltage | V1-V2 | 230V-1*15KV | ||||
I1-I2 | 1A-25mA | |||||
Operation mode | Intermittent operation must be shut down every 24 hours |
The following is the process you should take to complete your order through bank to bank transfer:
1. Please go to your bank (through online banking, ATM or going into a branch) and complete the transfer of money. Make sure that the amount you transfer is the exact total of your order. Payment details below:
- If your bank is located in Austria, Germany, Spain, France, United Kingdom, Italy, Netherlands, Belgium, Finland, Greece or Luxemburg you will pay to our WorldPay bank. You will see the bank details once you have placed the order.
PLEASE NOTE: If you are paying to our WorldPay bank you MUST include the Unique Payment Reference Number (you will receive this directly after paying the order) in the description section when completing payment to help us identify your order. Failure to do this will result in an unsuccessful transaction.
- If your bank is located in a country not listed above you will pay to our HSBC account. The details are below:
Bank Account:
Bank Code:
Beneficiary:
Bank Name:
Bank Address:
SWIFT Code:
PLEASE NOTE: If you are paying in this way you MUST write your Yourname order number in the description section when paying so we can easily recognize your payment. Failure to do this will result in a delayed or failed transaction.
2. When this is done, log in to your Yourname ‘My Account’ and complete the following:
Click ‘Order list’
Click ‘Pay’
Click ‘Complete Payment’ and fill in the related information for verification (This is an important step. If the information you have filled in does not match your bank details the payment can not be completed.)
Click ‘Submit’ to finish the procedure.
3. You will receive a payment confirmation email from us after your order’s payment has gone through successfully. If you do not receive this email, please contact us here: http://www.Yourname.com/help/
Please note that Yourname will begin to handle your items after payment has been cleared.
The tailoring and handling time is the number of business days we will take to process your items before shipping them. This processing includes order verification, item manufacturing, quality checking and packaging. This does not include the shipping time.
Different items and categories have different tailoring and handling times. However, on each item page the information is displayed next to the item photo as shown in the picture below.