BN STx (E30x) flue gas analyzer introduction:
application | BN STx (E30x) flue gas analyzer is widely used in small and medium combustion systems that use gas, fuel oil and solid particulates as fuel, such as burners, gas wall-hung boilers, gas water heaters, oil boilers and other thermal energy equipment. E30x is your test for flue gas The ideal instrument for emissions, regulation of boiler combustion efficiency and heating system operation, to ensure that your combustion and heating system is always in optimal working condition, achieving low energy consumption, low emissions, and high heat! |
feature | • Chinese color screen, touch sensitive operation |
• Standard long-life electrochemical sensor, oxygen sensor service life ≥ 5 years; | |
• Pipeline air tightness test, pressure leakage (loss) measurement; | |
• Barometric pressure measurement; | |
• Environmental CO monitoring, speaker alarm function; | |
• Standard low energy bluetooth communication, bluetooth printing and infrared printing functions; | |
• The measurement process can be monitored remotely through a mobile phone/pad/computer: graphs and histograms of the measured values are displayed; | |
• Built-in QR code function, after scanning the QR code, the measurement data can be directly saved in the mobile phone; | |
• Independent SD memory card, Max. 32GB; | |
• Optional: flow rate/flow measurement function; | |
• Optional: automatic recording function of measurement data, custom recording time interval 1-999S; | |
• The cruising time of the lithium battery is up to 14h, and it can be charged at the same time during the measurement; | |
• Scheduled shutdown and automatic flushing function before shutdown; | |
• Automatic calculation of CO2, NOx, CO undiluted, efficiency, excess air, flue gas loss, fuel dew point, etc. | |
describe | The EurOlyzer STx (E30x) handheld flue gas analyzer has a streamlined design, a durable and wear-resistant protective cover with magnet adsorption, enabling hands-free operation and maximum convenience for your daily use. |
AFRISO engineers have given the E30x the most advanced technological processes, such as: high-definition TFT color screen and touch-sensitive operation panel. The built-in flue core temperature search function can help you choose the best flue gas sampling point. The instrument has power-on self-test and limit monitoring functions, and automatically displays maintenance information for easy maintenance. In addition to the configuration of the miniUSB interface, the device can also be equipped with a Bluetooth interface to realize wireless data communication with the PC. Connect an external printer through the infrared interface to print the measurement data in real time. | |
Through low-energy bluetooth, remote control and wireless data communication with smart phones, tablet computers and PCs are realized. (See EurOSoft mObile software for details) |
BN STx (E30x) flue gas analyzer technical parameters:
Measurement parameters | range | Accuracy | Resolution | Response time (T90) |
O2 | 0~25 VOl.% | ±0.2 VOl.% measured value | 0.01Vol.% | <30 S |
CO(H compensation) | 0~5,000/10,000 ppm | ±5 ppm (<50 ppm) | 1 ppm | <30 S |
±5% of measured value (>50 ppm) | ||||
H | 0~2,000 ppm | ±5 ppm (<50 ppm) | 1 ppm | <30 S |
±5% of measured value (>50 ppm) | ||||
CO2-Calculation | O ~ CO2max | Soil 0.2 VOl.% | 0.1 VOl.% | <30 S |
NO | 0~2,000/ 5,000 ppm | ±2ppm (0~40ppm) | 0.1 ppm | <35S |
+5% of measured value (>40ppm) | ||||
NOx-Calculation | 0~6,000 ppm | ±2 ppm (0~40ppm) | 0.1 ppm | |
± 5% measured value (>40ppm) | ||||
flue gas temperature | 0~+1,00O°C | ±1°C (<+300°C) | 0.1°C | <10S |
±1% of measured value (>+300°C) | ||||
ambient temperature | -20~ +200 °C | 13℃+1 (-20~O℃) | 0.1°C | <10 S |
1℃+1 (0.1~+200℃ | ||||
Pulling force/differential pressure | ±150 hPa | ±2 Pa+1 (<2 hPa) | 0.01hPa(<19.9 hPa) | <10 S |
±1% of measured value (>2 hPa) | 0.1hPa (>20 hPa) | |||
flow rate | 0.5~70 m/S | MaxO.8m / S | 0.1 mlS | <20 S |
Display calculated values: CO, COunv (undiluted), temperature difference, combustion efficiency, excess air, flue gas loss, COref (carbon monoxide reference oxygen conversion value), flue gas dew point temperature
Dimensions (WxHxD) | 215×70 × 40 mm |
weight | 500g (including magnetic protective case) |
shell material | high-strength plastic |
display | TFT color display 2.8″ |
data communication | Bluetooth Low Energy |
storage | Optional MCrOSD/SDHC card, Max32 GB |
battery information | Lithium battery, 3.6V/1800mAh |
main power | Mini uSB (5v |
Operating temperature | -20~+40°C |
storage temperature | -20℃~+50℃ |
Protection class | IP42 (EN 60529) |
BN STx (E30x) flue gas analyzer model table:
describe | order number |
E30x mainframe | |
E30x O2, COHz, flue gas temperature, ambient temperature (instrument only) | MO46 29 010 |
E30x O, COHz, flue gas temperature, ambient temperature, suction force l differential pressure (instrument only) | M04629 210 |
E30x O, COH2, NO (NOx), flue gas temperature, ambient temperature (only instrument) | M04630 010 |
E30x O2, COH2, NO (NOx), flue gas temperature, ambient temperature, suction/differential pressure (instrument only) | M04630 210 |
Standard | |
Portable Instrument Case | 500541C |
Flue gas sampling probe: 290 mm probe, 1.8 m hose, without suction measurement interface, | 500264 |
Flue gas sampling probe: 290 mm probe, 1.8m hose, with suction measurement interface | 500267 |
Flue gas condensate filter (used in conjunction with sampling probe) | 500190 |
Ambient temperature probe | 521844 |
uSB interface charger unit | 523493 |
uSB interface charging cable 1.0m | 523506 |
Spare consumables: Combination of soot fine filter (5 pieces) and soot TeflOn filter (5 pieces) | 500208 |
Optional | |
Extended NO measurement function (NOINOx) | 522680 |
infrared printer | 522394.2 |
Bluetooth printer l | 523525 |
Thermal printing paper (5 rolls) | 523374 |
Velocity/Flow Measurement | 510913 |
Measurement data automatic recording program | 511010 |
Low energy bluetooth communication control module (suitable for remote control of the instrument by PC) | 500856 |
Flue gas analyzer selection guide:
Note:● It is standard * is optional
The following is the process you should take to complete your order through bank to bank transfer:
1. Please go to your bank (through online banking, ATM or going into a branch) and complete the transfer of money. Make sure that the amount you transfer is the exact total of your order. Payment details below:
- If your bank is located in Austria, Germany, Spain, France, United Kingdom, Italy, Netherlands, Belgium, Finland, Greece or Luxemburg you will pay to our WorldPay bank. You will see the bank details once you have placed the order.
PLEASE NOTE: If you are paying to our WorldPay bank you MUST include the Unique Payment Reference Number (you will receive this directly after paying the order) in the description section when completing payment to help us identify your order. Failure to do this will result in an unsuccessful transaction.
- If your bank is located in a country not listed above you will pay to our HSBC account. The details are below:
Bank Account:
Bank Code:
Beneficiary:
Bank Name:
Bank Address:
SWIFT Code:
PLEASE NOTE: If you are paying in this way you MUST write your Yourname order number in the description section when paying so we can easily recognize your payment. Failure to do this will result in a delayed or failed transaction.
2. When this is done, log in to your Yourname ‘My Account’ and complete the following:
Click ‘Order list’
Click ‘Pay’
Click ‘Complete Payment’ and fill in the related information for verification (This is an important step. If the information you have filled in does not match your bank details the payment can not be completed.)
Click ‘Submit’ to finish the procedure.
3. You will receive a payment confirmation email from us after your order’s payment has gone through successfully. If you do not receive this email, please contact us here: http://www.Yourname.com/help/
Please note that Yourname will begin to handle your items after payment has been cleared.
The tailoring and handling time is the number of business days we will take to process your items before shipping them. This processing includes order verification, item manufacturing, quality checking and packaging. This does not include the shipping time.
Different items and categories have different tailoring and handling times. However, on each item page the information is displayed next to the item photo as shown in the picture below.