0 Cart
  • Free Shipping over $199.99

  • 5% Off Discount Code: wowo

  • Promotion Time (01.01-12.31)

  • day ::

This product was successfully added to cart!

View Shopping Cart

Low pressure regulator BN CS400 Series stable performance, large film pressure regulation and high regulation accuracy

Low pressure regulator BN CS400 Series stable performance, large film pressure regulation and high regulation accuracy

SKU: #001 - In Stock
USD$112.00 USD$95.00 (% off)

  • airport Shipping:  International shipping available
  •  Shipping time:   Standar(10-20 business days), Rush(5-10 business days)
  • chip Discount:  Get 2% discount on orders of USD $100.00,Get 3% discount on orders of USD $200.00
  • compass Handling time:  Ships within 3 business days after receiving cleared payment
  • available_updates Returns:  7 days money back guaratee,buyer pays return shipping

Product Detail

Customer Reviews

Shipping Guide

Delivery Time

Product Tags

Low pressure regulator BN CS400 Series stable performance, large film pressure regulation and high regulation accuracy

application

The cs400 series direct operated spring loaded regulators have been designed for a wide range of pressure reducing applications, including commercial and industrial installations. It can be used for natural gas, artificial gas, liquefied petroleum gas, air and other gases. Because of its stable performance, large film pressure regulation and high regulation accuracy.

Main features

Material : Cast aluminum + cast iron
Spring : Steel
Diaphragm : Synthetic rubber
Ambient temperature: -15℃…+ 60℃
Connection : Threaded

Parameters

Model Caliber Max.inlet pressure outlet pressure Flow
BNCS400-40 RP1/2″ 10.3bar(sug2bar) 7-15bar 190m³(Air)
BNCS400-50 Rp2″ 10.3bar(sug2bar) 7-15bar 210m³(Air)

The outlet pressure of wfcs400 pressure regulating valve is 7-15kpa by default. If you need other outlet  pressure, please contact the relevant salesperson! Other size—(3kpa-7kpa ) OR (15kpa-30kpa)

6-3 

 

Install

CS400 series regulators can be installed in any position. However, the spring case vent should face down. If the exhaust gas is to be piped to another location, use a non blocking pipe at least the same size as the vent, and the end of the vent must be protected from any objects that may block it. Before installation, the pipeline shall be purged to clean the return impurities in the pipeline, so as to avoid impurities entering into the valve chamber, which will cause the regulator to fail to work normally. During installation, the air flow direction should be consistent with the arrow direction indicated on the valve seat.

setting

After installation, screw off the plastic cover on the valve body, and thenuse a screw  driver to adjust the pressure spring cover inside. Turn clockwise,the outlet pressure increases, and turn counterclockwise, the outlet pressure decreases.

Maintenance

Regularly check whether the pipeline is blocked and whether the pressure gauge in front of the pressure reducing valve works normally. Remove dirt regularly. If there is a problem with the regulating valve, please contact the manufacturer for feedback and support, and carry out maintenance and test if necessary. It is recommended that safety valves be used upstream or downstream of these control valves.

 

 


 

Write a review here:

  • 1 Star2 Stars3 Stars4 Stars5 Stars (No Ratings Yet)
    Loading ... Loading ...

  • 3 + one =

  • JPEG only
  • The following is the process you should take to complete your order through bank to bank transfer:

    1. Please go to your bank (through online banking, ATM or going into a branch) and complete the transfer of money. Make sure that the amount you transfer is the exact total of your order. Payment details below:

    - If your bank is located in Austria, Germany, Spain, France, United Kingdom, Italy, Netherlands, Belgium, Finland, Greece or Luxemburg you will pay to our WorldPay bank. You will see the bank details once you have placed the order.

    PLEASE NOTE: If you are paying to our WorldPay bank you MUST include the Unique Payment Reference Number (you will receive this directly after paying the order) in the description section when completing payment to help us identify your order. Failure to do this will result in an unsuccessful transaction.

    - If your bank is located in a country not listed above you will pay to our HSBC account. The details are below:

    Bank Account:
    Bank Code:
    Beneficiary:
    Bank Name:
    Bank Address:
    SWIFT Code:

    PLEASE NOTE: If you are paying in this way you MUST write your Yourname order number in the description section when paying so we can easily recognize your payment. Failure to do this will result in a delayed or failed transaction.

    2. When this is done, log in to your Yourname ‘My Account’ and complete the following:

    Click ‘Order list’
    Click ‘Pay’
    Click ‘Complete Payment’ and fill in the related information for verification (This is an important step. If the information you have filled in does not match your bank details the payment can not be completed.)
    Click ‘Submit’ to finish the procedure.

    3. You will receive a payment confirmation email from us after your order’s payment has gone through successfully. If you do not receive this email, please contact us here: http://www.Yourname.com/help/

    Please note that Yourname will begin to handle your items after payment has been cleared.

    The tailoring and handling time is the number of business days we will take to process your items before shipping them. This processing includes order verification, item manufacturing, quality checking and packaging. This does not include the shipping time.

    Different items and categories have different tailoring and handling times. However, on each item page the information is displayed next to the item photo as shown in the picture below.

    Tags: , , , , , , ,

    Customers Also Bought:

    Copper valve series

    USD$42.00 USD$26.00

    INQUIRY DETAILS *

    INQUIRY NOW
    • captcha