0 Cart
  • Free Shipping over $199.99

  • 5% Off Discount Code: wowo

  • Promotion Time (01.01-12.31)

  • day ::

This product was successfully added to cart!

View Shopping Cart

Gas Filter BNM15-150/F Series protects equipment reduces clogging reduce the risk of sudden blockages

Gas Filter BNM15-150/F Series protects equipment reduces clogging reduce the risk of sudden blockages

SKU: #001 - In Stock
USD$60.00 USD$50.00 (% off)

  • airport Shipping:  International shipping available
  •  Shipping time:   Standar(10-20 business days), Rush(5-10 business days)
  • chip Discount:  Get 2% discount on orders of USD $100.00,Get 3% discount on orders of USD $200.00
  • compass Handling time:  Ships within 3 business days after receiving cleared payment
  • available_updates Returns:  7 days money back guaratee,buyer pays return shipping

Product Detail

Customer Reviews

Shipping Guide

Delivery Time

Product Tags

Gas filter BNM15-150/F series protection device reduces clogging and reduces risk of sudden clogging

parameter

Ambient temperature: -20℃~+70℃ Filtration
accuracy :≥50μm Gas product

material: aluminum alloy body, galvanized steel, nitrile rubber ring
1-5 1-3

Application
1.This device is used to suppress the dust particles carried in the gas,to protect the equipment (gas appliances, calculators, regulators), andto reduce the risk of sudden blockage.
2.The gas filter includes a filter box made of man-made fiber material,which can be completely extracted for overall inspection and thoroughcleaning.
3.The device is designed with special O-ring, easy to use and resistantto three kinds of domestic gases。

Installation
1. Please close the gas supply valve before installation. Check the pipepressure to ensure that the maximum pressure specified on the productlabel is not exceeded;
2. The gas filter is usually installed upstream with regulating andswitch-ing devices. The arrow on the installed filter (3) must point in the direction of the device being used;
3. The filter shall be installed at any place that will not interfere with the normal operation of the equipment. During the installation, pleasetake care to avoid debris or metal waste entering the filter
4. If the filter adopts threaded connection, please check and ensure that the pipe thread is not too long; if the thread is too long, the filter body will be damaged during installation. The connection of pipes and fittings must conform to the connection thread of the filter.
5. If the filter adopts flange continuous blow, please check that the butt flanges at the inlet and outlet match each other to avoid unnecessary mechanical pressure on the filter body. The system must be air tight after installation.
Maintenance
In each case , make sure to do the following before performing any intermediate checks.
1. Disconnect the power supply from the devic
2. No pressurized gas in the filter. Remove the top cover (1), unscrew the set screw (5), wash with soap and water, blow with compressed air (or a suitable substitute), and put it back in place, check that it is in the guide groove (4), Then check that the top cover (1) can be installed.

Backup PictuerAlbum.cdr

Write a review here:

  • 1 Star2 Stars3 Stars4 Stars5 Stars (No Ratings Yet)
    Loading ... Loading ...

  • 8 − = one

  • JPEG only
  • The following is the process you should take to complete your order through bank to bank transfer:

    1. Please go to your bank (through online banking, ATM or going into a branch) and complete the transfer of money. Make sure that the amount you transfer is the exact total of your order. Payment details below:

    - If your bank is located in Austria, Germany, Spain, France, United Kingdom, Italy, Netherlands, Belgium, Finland, Greece or Luxemburg you will pay to our WorldPay bank. You will see the bank details once you have placed the order.

    PLEASE NOTE: If you are paying to our WorldPay bank you MUST include the Unique Payment Reference Number (you will receive this directly after paying the order) in the description section when completing payment to help us identify your order. Failure to do this will result in an unsuccessful transaction.

    - If your bank is located in a country not listed above you will pay to our HSBC account. The details are below:

    Bank Account:
    Bank Code:
    Beneficiary:
    Bank Name:
    Bank Address:
    SWIFT Code:

    PLEASE NOTE: If you are paying in this way you MUST write your Yourname order number in the description section when paying so we can easily recognize your payment. Failure to do this will result in a delayed or failed transaction.

    2. When this is done, log in to your Yourname ‘My Account’ and complete the following:

    Click ‘Order list’
    Click ‘Pay’
    Click ‘Complete Payment’ and fill in the related information for verification (This is an important step. If the information you have filled in does not match your bank details the payment can not be completed.)
    Click ‘Submit’ to finish the procedure.

    3. You will receive a payment confirmation email from us after your order’s payment has gone through successfully. If you do not receive this email, please contact us here: http://www.Yourname.com/help/

    Please note that Yourname will begin to handle your items after payment has been cleared.

    The tailoring and handling time is the number of business days we will take to process your items before shipping them. This processing includes order verification, item manufacturing, quality checking and packaging. This does not include the shipping time.

    Different items and categories have different tailoring and handling times. However, on each item page the information is displayed next to the item photo as shown in the picture below.

    Tags: , , , , , , , ,

    Customers Also Bought:

    INQUIRY DETAILS *

    INQUIRY NOW
    • captcha